Surveyors’ span tables for floor joists

 

Surveyors and structural engineers use data from tables below to help calculate the size of timbers necessary to give adequate support to timber floors.

These tables can help calculate whether floor joists are strong enough to support themselves and the load they carry, without the help of any walls underneath.  Building Control may ask for additional engineer’s calculations.

 

 

You can also download this excellent pdf span table guide  (includes C16, C24 and I-joists)

 

The weight of the timber floor itself consists of the timber joists, the plasterboard ceiling underneath it (except for suspended timber ground floors), the floorboards and the nails or screws used to fix both of the aforementioned coverings.

All of these are known as “the dead load” . The joists  must be able to support this dead load without sagging. This dead load is generally taken by architects and planners to be no more than 0.50 Kilo Newtons per square metre. (kN/sq.m)

The weight we place upon a floor by way of bathroom suites, beds, wardrobes etc, is known as the “imposed load”. It is again accepted that, for normal household requirements, the imposed load will not exceed 1.5kN/sq.m.

Unless C24 timber is specified, the more generally used timbers are less expensive C16.

This table is for a dead load of more than 0.25 but not more than 0.50 and allows for an imposed loading of no more than 1.5 kN/sq.m.

You need to measure the complete span of your floor joists, together with the distance between them (the ‘centres’) and the size of the timbers.

This should be compared to the table. If your old joists do not meet the requirements set by the table, they are either supported somewhere from underneath or they were installed pre regulations (November 1985).

 

Click for  STRUCTURAL DESIGN CALCULATIONS

 


 

RECOMMENDED  MAXIMUM  SPANS for C16 timber floor joists

 

Spacing  (distance apart) of joists – centres

Size of  joist mm   400mm   450mm   600mm

SPAN

metres

SPAN

metres

SPAN

metres

38 x 97 1.72 1.56 1.21
38 x 122 2.37 2.22 1.76
38 x 140 2.72 2.59 2.17
38 x 147 2.85 2.71 2.33
38 x 170 3.28 3.1 2.69
38 x 184 3.53 3.33 2.9
38 x 195 3.72 3.52 3.06
38 x 220 4.16 3.93 3.42
38 x 235 4.43 4.18 3.64
     
47 x 97   1.92 1.82 1.46
47 x 122 2.55 2.45 2.09
47 x 147 3.06 2.95 2.61
47 x 170 3.53 3.4 2.99
47 x 195 4.04 3.89 3.39
47 x 220 4.55 4.35 3.79
       
50 x 97 1.98 1.87 1.54
50 x 122 2.6 2.5 2.19
50 x 147   3.13   3.01   2.69
50 x 170 3.61 3.47 3.08
50 x 195 4.13 3.97 3.5
50 x 220 4.64 4.47 3.91
       
63 x 97 2.19 2.08 1.82
63 x 122 2.81 2.7 2.45
63 x 147 3.37 3.24 2.95
63 x 170 3.89 3.74 3.4
63 x 195 4.44 4.28 3.9
63 x 220 4.91 4.77 4.37
       
75 x 122 2.97 2.86 2.6
75 x 147 3.56 3.43 3.13
75 x 170 4.11 3.96 3.61
75 x 195 4.68 4.52 4.13
75 x 220 5.11 4.97 4.64

This is an abridged representation of  Building regulations Table A1

 

 

Click for  STRUCTURAL DESIGN CALCULATIONS

 


 

MAXIMUM  SPANS for C24 timber floor joists

 

Permissible clear spans for domestic floor joists – strength class C24

Imposed load not exceeding 1.5 kN/m2
Service Class 1 or 2

Dead Load [kN/m2] excluding self-weight of joist
  Not more than 0.25 More than 0.25 but not more than 0.50 More than 0.50 but not more than 1.25
Size of joist Spacing of joists [mm]
  400 450 600 400 450 600 400 450 600
Breadth [mm] Depth [mm] Maximum clear span [m]
38 97 2.03 1.91 1.66 1.92 1.82 1.58 1.70 1.62 1.36
38 122 2.67 2.57 2.30 2.55 2.45 2.17 2.27 2.16 1.88
38 147 3.21 3.09 2.80 3.07 2.95 2.67 2.76 2.65 2.39
38 170 3.71 3.56 3.23 3.55 3.41 3.09 3.18 3.06 2.74
38 195 4.24 4.08 3.71 4.06 3.90 3.54 3.65 3.50 3.12
38 220 4.75 4.60 4.17 4.57 4.40 3.99 4.11 3.95 3.49
                     
47 97 2.24 2.12 1.85 2.12 2.01 1.75 1.87 1.78 1.56
47 122 2.87 2.76 2.50 2.74 2.64 2.39 2.46 2.36 2.09
47 147 3.45 3.31 3.01 3.30 3.17 2.88 2.96 2.85 2.58
47 170 3.98 3.83 3.48 3.81 3.66 3.32 3.42 3.29 2.98
47 195 4.55 4.38 3.98 4.36 4.19 3.81 3.92 3.77 3.41
47 220 5.00 4.86 4.48 4.84 4.70 4.29 4.41 4.24 3.85
                     
63 97 2.52 2.42 2.13 2.41 2.29 2.01 2.12 2.01 1.78
63 122 3.16 3.04 2.76 3.02 2.91 2.64 2.72 2.61 2.37
63 147 3.79 3.65 3.32 3.63 3.49 3.18 3.27 3.14 2.85
63 170 4.37 4.21 3.83 4.19 4.03 3.67 3.77 3.63 3.29
63 195 4.91 4.77 4.39 4.76 4.61 4.20 4.32 4.15 3.77
63 220 5.36 5.21 4.86 5.19 5.05 4.71 4.81 4.67 4.25
                     
75 122 3.34 3.22 2.93 3.20 3.08 2.80 2.88 2.77 2.51
75 147 4.01 3.86 3.52 3.84 3.70 3.37 3.46 3.33 3.03
75 170 4.62 4.45 4.06 4.43 4.27 3.88 4.00 3.84 3.49
75 195 5.12 4.98 4.64 4.96 4.82 4.45 4.57 4.40 4.00
75 220 5.59 5.43 5.07 5.41 5.26 4.91 5.02 4.88 4.51
ALS/CLS
38 140 3.06 2.94 2.67 2.93 2.81 2.55 2.63 2.52 2.25
38 184 4.01 3.85 3.50 3.83 3.69 3.34 3.44 3.31 2.95
38 235 4.98 4.84 4.46 4.82 4.68 4.26 4.39 4.21 3.71

Source:  NHBC / TRADA

 

Click for  STRUCTURAL DESIGN CALCULATIONS

 


 

Beam & Block / Suspended Concrete Floors

Ceiling joists

for non habitable loft floors – C16 strength grade timber

 

 

FREE

pdf

DOWNLOADS

Floor Design Advice

 

BUILDING CONTROL GUIDANCE

 